Seitenansicht 130
Service Training
Page 4.2
Section 73
09.04
noyes
O
noyes
noyes
Remove adapters II with plugs and screw into ports YF and ZF. Determine Δp
with the brake released.
noyes
Δp now 0 bar to
max. 0,5 bar.
PQ
Δp 0 bar to max. 0,5 bar.
Δp now 0 bar to
max. 0,5 bar.
Remove adapters III and screw in adapters II with plugs. Install LP gauges and
determine Δp with the brake released.
Install LP gauge with adapter III to ports Y and Z of remote control and
determine Δp with the brake released.
Average wheel
speed of 155 - 165 rpm
achieved on both
sides.
Leak in remote control.
Remedy fault or renew
remote control.
Leak in power limiter
control block. Remedy
fault or renew control
block.
Travel control unit not
okay. Check setting and
adjust, if necessary, or
renew travel control unit.
Seitenansicht 130