5.1 Maintenance Schedule Routine Maintenance
Additions and modifications
for engines with EPA approval
The specified engine maintenance values are permissible
recommended maximums. Depending on usage, reduced
maintenance intervals may be necessary, comply with the
unit manufacturer’s operating instructions.
# Maintenance must only be carried out by authorised
service personnel
check = adjust = clean = replace =
max. recommended standard times in operating hours (HO) of all
prior to or during 1st trial run, check 2x daily during the breaking in phase or when
commissioning new and overhauled engines
every 10 hours of operation or daily
In hours of operation (HO) every
Operation Section
Injection valve #
Intercooler (drain lube oil/condensation) #
CPD compressor outlet #
Basic overhaul of emission related parts #
E10 E20 E30 E40 E50 E60 E70
250 500 1000 2000 3000 4000 1 2