Deutz 914 Technical Information Seite 59

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 85
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 58
6
© 2001
Empty dust discharge valve 1 by pressing
apart lips of discharge slot as indicated by
arrows.
Clean discharge slot from time to time.
Remove any caked dirt by pressing to-
gether the upper section of the valve.
Undo clip fasteners 1.
Take off hood 2 and remove cartridge 3.
Clean cartridge (replace at least once a
year).
Clean cartridge 3.
Blow out using dry compressed air (max.
5 bar), (or in difficult cases, tap out, taking
care not to damage the cartridge, or wash
according to manufacturer’s instructions).
Through regular removal and replacement,
the gaskets on the filter cartridge can
become damaged. Check paper filter (light
showing through) and gaskets for dam-
age.
Replace if necessary.
Never clean filter cartridge with
gasoline or hot fluids.
After five cleaner services (or after two
years at the latest), replace safety car-
tridge 4 (never clean).
To do so:
- Undo hex. nut 5 and remove cartridge 4.
- Install new cartridge, insert and tighten
hex nut.
Install cartridge 3, replace hood 2 and do up
clip fasteners 1.
6.4 Combustion Air Filter Service and Maintenance
6.4.4 Dry type air cleaner
Dust discharge valvel
Filter Cartridge
© 25 888 1 © 25 889 0
Seitenansicht 58