Deutz 914 Technical Information Seite 71

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 85
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 70
6
© 2001
6.9 Additional Maintenance Work Service and Maintenance
Test step 2
● Loosen screw 1.
● Turn engine over with starter, key in switch-
ing position 3.
● Fuel must be present on the loosened pipe
connection. Otherwise, the system and
solenoid valve should be checked by a
specialist!
Test step 3
● Loosen screw 1.
● Remove glow lamps 2
● Turn engine over with starter, key in switch-
ing position 3.
● Fuel must be present on the glow lamps 2,
or replace glow lamps 2 if necessary.
● When fitting glow lamps 2, use DEUTZ DW
47 sealants.
● Reinstall glow lamps to fuel line.
Keep away from moving parts!
Collect any escaping fuel and
dispose of this in an environ-
mentally-friendly manner.
© 24 717 1
© 24 717 1
Seitenansicht 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 84 85

Kommentare zu diesen Handbüchern

Keine Kommentare