3
© 2001
● Checking battery and cable connectors
see 6.7.1
● Transport hooks
Remove if fitted (see 6.7.3)
● Trial run
After the engine has been prepared, let it run
for about 10 minutes without load.
During and after trial run
– Check the engine for leaks.
After the engine has been turned off
– Check the oil level, see 6.1.2
If necessary, top up oil, see 3.1.1
– Retension V-belts, see 6.5.
● Breaking in
During the break-in phase, about 200 oper-
ating hours, check the oil level twice a day.
After the engine is broken in, checking once
a day will be sufficient.
3.1.6 Additional maintenance
work
Engine Operation 3.1 Commissioning
After 50-150 operating hours, the following
maintenance work is to be carried out:
● Change lube oil,
see 6.1.2
● Change oil filter cartridge,
see 6.1.3
● Change fuel filter cartridge,
see 6.2.1
●lCheck V-belts and retension as necessary,
see 6.5.
● Check valve clearance (adjust if neces-
sary) see 6.6.1
● Check the engine for leaks
● Check engine mounts (retighten if neces-
sary) see 9.2.
3.1.5 Other Preparations
3.1.7 Change-over switch for oil
heater
Position of change-over switch for oil filter
consoles with an oil heater connected:
Pos. 1: open
Pos. 2: closed
For engines without an oil
heater, the change-over switch
should
always be fixed to Pos.
2: closed.
© 30 027 0